Problem Possible Cause Correction
Engine will not start or stops operating. Low Oil Shutdown. Fill engine with oil.
Engine switch not in the "ON" position. Turn switch "ON".
Pressure build up in hose. Squeese Trigger.
Engine is overloaded. Nozzle partially blocked. Clean nozzle.
Excessive Pressure. Reduce pressure by using pressure adjustment knob.
Water or oil leaking from bottom of pump. A small amount of leakage is normal. If Excessive leaking occurs call the Customer Service Department.
Pressure increases when gun is closed. Bypass valve not operating properly. Call the Customer Service Department.
Engine running but pump not building maximum pressure or has irregular pressure. Faucet closed. Open Faucet.
Unit has been stored in freezing temperatures. Thaw out unit completely including hose, gun and wand.
Inadequate water supply. Provide a minimum of 4 gpm at 20 psi.
Water inlet screen clogged. Clean screen.
Kink in garden hose. Replace nozzle.
Air in pump. Let run with gun open and wand removed until steady stream of water is released.
Adjustable pressure knob not set to maximum position. Set to maximum position.
Suction or discharge valves clogged or worn out. Call the Customer Service Department.
By-pass valve not operating effectively. Call the Customer Service Department.
No intake of chemicals. Injection tube not securely inserted into unit. Push firmly into injector.
Tube cracked or split. Replace tubing.
Wrong nozzle. Switch to low pressure nozzle.
Injector turned off. Turn collar counter clockwise.
Injection tube strainer clogged. Clean strainer.
Nozzle blocked. Clean nozzle.
Dried chemicals injector. Dissolve by running warm water trough the injection tube.
Trigger will not move. Gun safety lock engaged. Release safety lock.
Water in crankcase. High humidity. Change oil more frequently.
Worn seals. Call the Customer Service Department
Noisy operation. Worn bearings. Call the Customer Service Department
Air mixed with water. Check inlet lines for restrictions and/or proper sizing.
Rough/pulsating operation with pressure drop. Worn Packing. Call the Customer Service Department.
Inlet Restriction. Check system for stoppage, air leaks, correctly sized inlet plumbing to pump.
Unloader. Check unloader for proper operation.
Air mixed in water Check inlet lines for restrictions and/or proper sizing.
High crankcase temperature. Wrong grade of oil. Check inlet lines for restrictions and/or proper sizing.
Improper amount of oil in crankcase. Adjust oil level to proper amount.